DREIERETNV. 40A ELINK 24VDC FJ LC2D40A3BD

Produktnummer
4179696
TeSys D reversing contactor, 3p(3 NO), AC-3, <= 440 V 40A, 24 V DC coil
TeSys D reversing contactor, 3p(3 NO), AC-3, <= 440 V 40A, 24 V DC coil. range: TeSys - product name: TeSys D - device short name: LC2D - contactor application: motor control, resistive load - utilisation category: AC-1, AC-3 - device presentation: preassembled with reversing power busbar - poles description: 3P - pole contact composition: 3 NO - [Ue] rated operational voltage: <= 300 V DC for power circuit, <= 690 V AC 25...400 Hz for power circuit - [Ie] rated operational current: 40 A (<= 60 °C) at <= 440 V AC AC-3 for power circuit, 60 A (<= 60 °C) at <= 440 V AC AC-1 for power circuit - motor power kW: 11 kW at 220...230 V AC 50/60 Hz, 18.5 kW at 380...400 V AC 50/60 Hz, 22 kW at 415...440 V AC 50/60 Hz, 22 kW at 500 V AC 50/60 Hz, 30 kW at 660...690 V AC 50/60 Hz - motor power hp: 10 hp at 200/208 V AC 50/60 Hz for 3 phases motors, 10 hp at 230/240 V AC 50/60 Hz for 3 phases motors, 3 hp at 115 V AC 50/60 Hz for 1 phase motors, 30 hp at 460/480 V AC 50/60 Hz for 3 phases motors, 30 hp at 575/600 V AC 50/60 Hz for 3 phases motors, 5 hp at 230/240 V AC 50/60 Hz for 1 phase motors - auxiliary contact composition: 1 NO + 1 NC - overvoltage category: III - [Ith] conventional free air thermal current: 10 A at <= 60 °C for signalling circuit, 60 A at <= 60 °C for power circuit - Irms rated making capacity: 140 A AC for signalling circuit conforming to IEC 60947-5-1, 250 A DC for signalling circuit conforming to IEC 60947-5-1, 800 A at 440 V for power circuit conforming to IEC 60947 - [Icw] rated short-time withstand current: 100 A 1 s signalling circuit, 120 A 500 ms signalling circuit, 140 A 100 ms signalling circuit, 165 A <= 40 °C 1 min power circuit, 320 A <= 40 °C 10 s power circuit, 72 A <= 40 °C 10 min power circuit, 720 A <= 40 °C 1 s power circuit - associated fuse rating: 10 A gG for signalling circuit conforming to IEC 60947-5-1, 80 A gG at <= 690 V coordination type 1 for power circuit, 80 A gG at <= 690 V coordination type 2 for power circuit - [Ui] rated insulation voltage: 600 V for power circuit certifications CSA, 600 V for power circuit certifications UL, 600 V for signalling circuit certifications CSA, 600 V for signalling circuit certifications UL, 690 V for power circuit conforming to IEC 60947-4-1, 690 V for signalling circuit conforming to IEC 60947-1 - electrical durability: 1.4 Mcycles 60 A AC-1 at Ue <= 440 V, 1.5 Mcycles 40 A AC-3 at Ue <= 440 V - power dissipation per pole: 2.4 W AC-3, 5.4 W AC-1 - protective cover: with - interlocking type: mechanical - mounting support: plate, rail - standards: CSA C22.2 No 14, EN 60947-4-1, EN 60947-5-1, IEC 60947-4-1, IEC 60947-5-1, UL 508 - product certifications: CCC, CSA, GOST, UL - connections - terminals: control circuit : spring terminals 1 cable(s) 0.75...2.5 mm² - cable stiffness: flexible - without cable end, control circuit : spring terminals 2 cable(s) 0.75...2.5 mm² - cable stiffness: flexible - without cable end, power circuit : EverLink BTR screw connectors 1 cable(s) 1...35 mm² - cable stiffness: flexible - with cable end, power circuit : EverLink BTR screw connectors 1 cable(s) 1...35 mm² - cable stiffness: flexible - without cable end, power circuit : EverLink BTR screw connectors 1 cable(s) 1...35 mm² - cable stiffness: solid - without cable end, power circuit : EverLink BTR screw connectors 2 cable(s) 1...25 mm² - cable stiffness: flexible - with cable end, power circuit : EverLink BTR screw connectors 2 cable(s) 1...25 mm² - cable stiffness: flexible - without cable end, power circuit : EverLink BTR screw connectors 2 cable(s) 1...25 mm² - cable stiffness: solid - without cable end - tightening torque: power circuit : 5 N.m - on EverLink BTR screw connectors - cable <= 25 mm² hexagonal 4 mm, power circuit : 8 N.m - on EverLink BTR screw connectors - cable 25...35 mm² hexagonal 4 mm - operating time: 16...24 ms opening, 42.5...57.5 ms closing - safety reliability level: B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1, B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1 - mechanical durability: 10 Mcycles. Benefits: In addition to its new look, the TeSys D contactor offers you quick simple setup, while maintaining a compact size of 45 and 55mm (40 to 65A) as well as compliance with international standards.. From 40 to 65A versions are equiped with EverLink, this new patented terminal technology, assures a permanent tightening quality even in the event of conductor creep.... Applications: Industry, infrastructure, building, etc:, TeSys D contactors have been designed for perfect integration in control systems, They can be used to create motor starters for any type of application., Switching contactor or relay coils, Powering control and signalling equipment....

Produktdetaljer

Teknisk spesifikasjon

Beskyttelsesklasse IPIP20
FunksjonVendebryter
Nominell effekt ved AC-3, 400V18.5 kW
Nominell matespenning ved AC 50 Hz0 ... 0 V
Nominell matespenning ved AC 60 Hz0 ... 0 V
Nominell matespenning ved DC24 ... 24 V
Nominell strøm Ie ved AC-3, 400 V40 A
Spenningstype for betjeningDC
Tilkoblingstype hovedstrømkretsTilkobling med fjærklemme

Produktnummer

SAPGBV519
Produktnummer4179696
Elnummer4179696
EAN/GTIN3389118341296
ProdusentnummerLC2D40A3BD
LeverandørnummerLC2D40A3BD

Standard informasjon

Pakkestørrelse (LxBxH)162 x 198 x 140 mm
Volum4.491 l
Vekt2.1 kg
Baseenhetstk
Pakkeenhet1
Usage quantity1
UNSPSC39121529
MerkeSCHNEIDER