CONTACTOR LC1DT32BL

Product number
4174168
TeSys D contactor, 4p(4 NO), AC-1, <= 440 V 32A, 24 V DC low cons coil
TeSys D contactor, 4p(4 NO), AC-1, <= 440 V 32A, 24 V DC low cons coil. range: TeSys - product name: TeSys D - product or component type: contactor - device short name: LC1D - contactor application: resistive load - utilisation category: AC-1 - poles description: 4P - pole contact composition: 4 NO - [Ue] rated operational voltage: <= 300 V DC for power circuit, <= 690 V AC 25...400 Hz for power circuit - auxiliary contact composition: 1 NO + 1 NC - overvoltage category: III - [Ith] conventional free air thermal current: 10 A at <= 60 °C for signalling circuit, 32 A at <= 60 °C for power circuit - Irms rated making capacity: 140 A AC for signalling circuit conforming to IEC 60947-5-1, 250 A DC for signalling circuit conforming to IEC 60947-5-1, 300 A at 440 V for power circuit conforming to IEC 60947 - [Icw] rated short-time withstand current: 100 A 1 s signalling circuit, 120 A 500 ms signalling circuit, 140 A 100 ms signalling circuit, 145 A <= 40 °C 10 s power circuit, 240 A <= 40 °C 1 s power circuit, 40 A <= 40 °C 10 min power circuit, 84 A <= 40 °C 1 min power circuit - associated fuse rating: 10 A gG for signalling circuit conforming to IEC 60947-5-1, 35 A gG at <= 690 V coordination type 2 for power circuit, 50 A gG at <= 690 V coordination type 1 for power circuit - [Ui] rated insulation voltage: 600 V for power circuit certifications CSA, 600 V for power circuit certifications UL, 600 V for signalling circuit certifications CSA, 600 V for signalling circuit certifications UL, 690 V for power circuit conforming to IEC 60947-4-1, 690 V for signalling circuit conforming to IEC 60947-1 - protective cover: with - mounting support: plate, rail - standards: CSA C22.2 No 14, EN 60947-4-1, EN 60947-5-1, IEC 60947-4-1, IEC 60947-5-1, UL 508 - product certifications: BV, CCC, CSA, DNV, GL, GOST, LROS, RINA, UL - connections - terminals: control circuit : screw clamp terminals 1 cable(s) 1...4 mm² - cable stiffness: flexible - with cable end, control circuit : screw clamp terminals 1 cable(s) 1...4 mm² - cable stiffness: flexible - without cable end, control circuit : screw clamp terminals 1 cable(s) 1...4 mm² - cable stiffness: solid - without cable end, control circuit : screw clamp terminals 2 cable(s) 1...2.5 mm² - cable stiffness: flexible - with cable end, control circuit : screw clamp terminals 2 cable(s) 1...4 mm² - cable stiffness: flexible - without cable end, control circuit : screw clamp terminals 2 cable(s) 1...4 mm² - cable stiffness: solid - without cable end, power circuit : connector 1 cable(s) 2.5...10 mm² - cable stiffness: flexible - with cable end, power circuit : connector 1 cable(s) 2.5...10 mm² - cable stiffness: flexible - without cable end, power circuit : connector 1 cable(s) 2.5...16 mm² - cable stiffness: solid - without cable end, power circuit : connector 2 cable(s) 2.5...10 mm² - cable stiffness: flexible - with cable end, power circuit : connector 2 cable(s) 2.5...10 mm² - cable stiffness: flexible - without cable end, power circuit : connector 2 cable(s) 2.5...16 mm² - cable stiffness: solid - without cable end - tightening torque: control circuit : 1.7 N.m - on screw clamp terminals - with screwdriver flat Ø 6 mm, control circuit : 1.7 N.m - on screw clamp terminals - with screwdriver Philips No 2, power circuit : 1.7 N.m - on connector - with screwdriver flat Ø 6 mm, power circuit : 1.7 N.m - on connector - with screwdriver Philips No 2 - operating time: 20...30 ms opening, 65.45...88.55 ms closing - safety reliability level: B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1, B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1 - mechanical durability: 30 Mcycles. Benefits: In addition to its new look, the TeSys D contactor offers you quick simple setup, while maintaining a compact size of 45 and 55mm (40 to 65A) as well as compliance with international standards.. From 40 to 65A versions are equiped with EverLink, this new patented terminal technology, assures a permanent tightening quality even in the event of conductor creep.... Applications: Industry, infrastructure, building, etc:, TeSys D contactors have been designed for perfect integration in control systems, They can be used to create motor starters for any type of application., Switching contactor or relay coils, Powering control and signalling equipment....

Product details

Technical specifications

Rated control supply voltage AC 50 Hz0 ... 0 V
Rated control supply voltage AC 60 Hz0 ... 0 V
Rated control supply voltage DC24 ... 24 V
Voltage type for actuatingDC
Number of normally closed contacts as main contact0
Number of normally open contacts as main contact4
Type of electrical connection of main circuitScrew connection
Rated operation current Ie at AC-1, 400 V32 A
Rated operation current Ie at AC-3, 400 V0 A
Rated operation power at AC-3, 400 V0 kW
Rated operation current Ie at AC-4, 400 V0 A
Rated operation power at AC-4, 400 V0 kW
Number of auxiliary contacts as normally open contact1
Number of auxiliary contacts as normally closed contact1
Modular versionfalse

Product codes

SAPACF669
PLC4174168
STK4174168
GTIN/EAN3389110248333
Manufacturer part numberLC1DT32BL
Vendor material numberLC1DT32BL

Basic information

Package measurements (L x W x H)99 x 45 x 90 mm
Package volume0.401 l
Package weight0.43 kg
Base uniteach
Package units1 / 12 / 120
Usage quantity
UNSPSC39121529
BrandSCHNEIDER