CONTACTOR 3RT1056-6AP36

Product number
4164734
CONTACTOR, 90KW/400V/AC-3
Power contactor, AC-3 185 A, 90 kW / 400 V AC (50-60 Hz) / DC operation 220-240 V UC Auxiliary contacts 2 NO + 2 NC 3-pole, Size S6 Busbar connections Drive: conventional screw terminal Power contactor SIRIUS 3RT1 for switching motors.The 3RT1 contactors are part of the modular SIRIUS system with its optimally coordinated products. They offer convincing performance from a compact design with high contact reliability. They can be combined with a variety of other components in the load feeder. The contactors offer the best connection to the automation level for every application (direct or via PLC input). Pre-installed auxiliary switches reduce the complexity of your design. The 3RT1 contactors are climate-resistant, approved for worldwide use (e.g. IEC and UL/CSA) and are IE3/IE4-ready.They are available in various sizes and in a wide performance range. They can be operated with AC or DC, and some versions have a wide voltage range and a PLC control input. The devices can be connected in the main circuit by means of rails or box terminals. For the auxiliary and control circuit they are also available with spring-type terminals for fast, maintenance-free and vibration-proof connection.A wide range of accessories is available for these contactors, such as wiring kits that considerably reduce wiring outlay, auxiliary switches or terminal covers.Simple, efficient and always up to date - SIRIUS modular system.

Product details

Technical specifications

Rated control supply voltage AC 50 Hz220 ... 240 V
Rated control supply voltage AC 60 Hz220 ... 240 V
Rated control supply voltage DC220 ... 240 V
Voltage type for actuatingAC/DC
Number of normally closed contacts as main contact0
Number of normally open contacts as main contact3
Type of electrical connection of main circuitScrew connection
Rated operation current Ie at AC-1, 400 V215 A
Rated operation current Ie at AC-3, 400 V185 A
Rated operation power at AC-3, 400 V104 kW
Rated operation current Ie at AC-4, 400 V160 A
Rated operation power at AC-4, 400 V90 kW
Number of auxiliary contacts as normally open contact2
Number of auxiliary contacts as normally closed contact2
Modular versiontrue

Product codes

SAPGBO959
PLC4164734
STK4164734
GTIN/EAN4011209507531
Manufacturer part number3RT1056-6AP36
Vendor material number3RT1056-6AP36

Basic information

Package measurements (L x W x H)457 x 239 x 277 mm
Package volume30.255 l
Package weight3.5 kg
Base uniteach
Package units1
Usage quantity
UNSPSC39121529
BrandSIEMENS AUTOMASJON